<style id="5cafh"></style>
    <style id="5cafh"></style>

  • <big id="5cafh"></big>
    1. <u id="5cafh"></u>
      <cite id="5cafh"></cite><style id="5cafh"></style>
      av天堂久久精品影音先锋,精品国产乱一区二区三区,97人妻精品一区二区三区,国产成人综合亚洲精品国产,亚洲国产女性内射第一区,国产精品日本一区二区不卡视频,国产肥臀视频一区二区三区 ,久久午夜私人影院
      首頁(yè) >>> 產(chǎn)品目錄 >>> 電力儀器儀表 >>> 三相交直流標(biāo)準(zhǔn)源
      工控網(wǎng) >>> 展館展區(qū) >>> JYM-303三相多功能標(biāo)準(zhǔn)表(英文版)
      > JYM-303三相多功能標(biāo)準(zhǔn)表(英文版)

      產(chǎn)品資料

      JYM-303三相多功能標(biāo)準(zhǔn)表(英文版)

      JYM-303三相多功能標(biāo)準(zhǔn)表(英文版)
      • 如果您對(duì)該產(chǎn)品感興趣的話,可以
      • 產(chǎn)品名稱:JYM-303三相多功能標(biāo)準(zhǔn)表(英文版)
      • 產(chǎn)品型號(hào):JYM-303
      • 產(chǎn)品展商:上海徐吉
      • 產(chǎn)品文檔:無相關(guān)文檔
      簡(jiǎn)單介紹
      JYM-303 meter, developed by our company, is a standard electric energy meter with characteristics of wide-range, multifunction and high-precision. It has accuracy grade of 0.02. By adopting techniques of DSP, embedded system and automatic temperature balancing and other compensation
      產(chǎn)品描述


      本產(chǎn)品由上海徐吉電氣有限公司精心推薦:


      產(chǎn)品特性:

      1. With cases of luxury sectional bar, A-series has a luxurious appearance. While with aluminum cases, B-series is portable, more smaller (it is the smallest one in domestic products of this kind. 355*145*185mm) , more lighter and easier to take.
      2. Wide-range measuring:
      Voltage measuring range (phase voltage):1~560V
         Current measuring range:                        10mA~120A
      3. Measurement of various ways: It has ability to measure AC voltage , current , power (active power, reactive power, apparent power) and electric energy in four-quadrant with connection modes such as single-phase and four-wire three-phase Y/ three-wire Δ. In addition, it can measure reactive power and electric energy with ways of true reactive, cross-phase reactive power, artificial neutral point of reactive.
      4. Multifunctional measurement:
      a. Fundamental function of measuring for voltage, current, phase, frequency, active power, reactive power, power factor and error.
      b. Measuring degree of stability of voltage, current and power.
      c.Measuring degree of asymmetry of voltage and current amplitude in three-phase circuits.
      d.Measuring degree of unbalancedness of voltage and current in three-phase circuits.
      e.Measuring degree of asymmetry of the phase.
      f.Display of vector diagram. There are a variety of display ways for vector diagram to meet the different display habits (such as clockwise rotation, counterclockwise rotation; the choice of the benchmark location between 12:00 o’clock and 3:00 o’clock; reference benchmark can be changeable; phase settings for display ways: 0~360°or ±180°).
      g.Waveform display, harmonic analysis, distortion calculation. Display of frequency spectrum, it can display the amplitude, contents and phase of the harmonic. Frequency spectrum can be enlarged.
      h.Dem measurement.
      i.Measurement of space magnetic induction intensity.
      j.Measurements of voltage drop of the device’s dotted terminal.
      k.Measurement of the constant and frequency of the meter to be adjusted.
      l.Measurement of power of fundamental wave.
      m. It can adjust errors of three different kinds of meters (active power, reactive power, apparent power, voltage, and current).
      n.There are three ports for pulses to output. And its constants can be set automatically or manually. Types of constants can be set also: active power, reactive power, apparent power, voltage, and current.
      o. It can check the comprehensive error of device composed of three single-phase meters.
      p. It can be used as three single-phase standard meters.
      5. Measurement of power for fundamental wave: not only could it measure the full power (including powers of fundamental wave and orders harmonics), but also the fundamental power only.
      6. Adjustment of electric energy error: it can adjust the estimate value of standard deviation and computation error of electric energy meters as well as calibration device for energy meter. Moreover, counts of pulse and constants of meters to be checked can be set automatically so as to work effectively. Especially for the multi-constant standard meter and the energy meter calibration device, it will be more convenient. By adopting the use of special compensation techniques, error-beating would not be large because of the small load (the low frequency of the energy pulses). It can display the current error, the value of the standard deviation estimate and the average error.
      7.  Harmonic analysis: it can analyze the harmonics of voltage and current under 51 orders.
      8. Display of data and graphics: it can display the measuring working condition and multiple measuring data directly. It can also display the waveform of the voltage and current to be measured, the phase vector graph of the voltage and current and waveform of harmonic analysis directly.
      9. The measuring range can be switched manually or automatically.
      10. With storage function, it can store 30 groups of data records which can be searched and browsed according to the condition.
      11. With the function of Pinyin input method: Chinese Character, alphabet and symbol can be inputted.
      12. Connection: the input port of the wide-range current is a public port, and there is no need to change connection mode while the current is changed, so it is very convenient to use.
      13. Multi-use: it can be used as a standard-meter, also as a calibration device for energy meter. It can be used alone, with PC by remote communication, also with calibration device.
      14. Multiple ports for communication: RS485, RS232, USB, and baud rate can be set when using asynchronous communication.
      15. With 6.4(or 5.7)-inch 640*480 pixel TFT display, it shows clearly and colorfully.
      16. Operation: human orient design, reasonable combination of the function and simple operating.


      產(chǎn)品參數(shù):

      1. Current measurement (Actual valid value RMS)
      Range:0.2A、1A、5A、20A、100A, range switch automatically
      Display range:0.00000mA~120.000A
      Measurement error:distorted wave:±0.02%RD(10mA~120A)
       Fundamental:±0.02%RD(10mA~120A)
       2~21 harmonic:±0.1%RD(10mA~120A)
      Measurement time base:1s~99s
      2.  Voltage measurement (Actual valid value RMS)
      Range:60V、120V、240V、480V  range switch automatically
      Display range:0.00000V~576.000V
      Measurement error:
      distorted wave:±0.02%RD(40V~576V)
       Fundamental:±0.02%RD(40V~576V)
      2~21 harmonic:±0.1%RD(40V~576V)
      Measurement time base:1s~99s
      3.  Power measurement
      Measurement error:
      Distorted wave active power:±0.02% RD(40V~576V,10mA~120A,PF≥0.5)
      Sine wave reactive power:±0.02% RD(40V~576V,10mA~120A,PF≥0.5)
      Sine wave apparent power:±0.02% RD(40V~576V,10mA~120A,PF≥0.5)
      Fundamental active power:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      2-21 harmonic active power:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      Display range:6 digital display
      4. Phase measurement(phase difference between each phase voltage and current)
      Measurement error:±0.01°(40V~576V,10mA~120A)
      Display range:0.000°~359.999°
      5.Power factor measurement(each phase power factor and three phase power factor)
      Measurement error:±0.0002(40V~576V,10mA~120A)
      Display error:-1.00000 ~ 0 ~ +1.00000
      6.Frequency measurement
      Measurement range:45~70Hz;
      Measurement error :±0.005%RD
      Display error:44.9999Hz ~ 69.9990Hz
      7.Harmonic content measurement
      Harmonic times:2…51 ( fundamental wave as 50Hz)
      Harmonic measurement error :±10%RD±0.1%(Rd as harmonic content reading)
      Distortion Measurement error :±10%RD±0.1%(Rd as distortion reading)
      8. Energy measurement
      Measurement error:
      Distorted wave active energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      Sine reactive energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      Sine active energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      Fundamental wave active energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      2-21 harmonic active energy:±0.1%(40V~576V,10mA~120A,PF≥0.5)
      Display error:(0.00…999999)Wh、varh、VAh
      9. Energy error measurement
      Tested meter constant range:1~999999999999imp/kWh(kvarh、kVAh)
      Pulse no. set range:1~9999999
      10. Tested energy pulse input
      Pulse electric level:5…12V
       input Frequency:2MHz (max)
      Min. pulse width:250ns
      Min. pulse interval:250ns
      11. Standard energy pulse output
      Pulse electric level:5V±5%,100mA
      Output frequency:Rated frequency60kHz (while voltage、current limit, power factor as 1)
      Max. frequency: 72kHz(While voltage limit、1.2 current limit,power factor as 1)
      12.Standard deviation evaluated value
      Voltage, current , active/reactive power, active/reactive energy                       standard deviation evaluated value≤0.002%
      13.Variation caused by influence quantity
      Measurement circuit voltage influence:≤0.004%(Power supply variation ±10%)
      Measurement circuit frequency influence:≤0.004%(Power supply variation ±10%)
      Auxiliary power supply voltage influence:≤0.002%(Power supply variation ±10%)
      Auxiliary power supply frequency influence:≤0.002%(Power supply variation±5%)
      Auxiliary power supply phase influence:≤0.002%
      Reverse phase influence:≤0.002%
      Current 3 times harmonic influence:≤0.004%
      AC external magnificent influence(1m,400 turns):≤0.01%
      14. Temperature
      Temperature coefficient:≤0.0005% /℃
      Self-heat influence:≤0.01%
      Pre-heat time:≤30min
      15.24h deviation:≤0.004%
      16. Insulation resistance:
      The insulation between voltage、current  input terminal and meter cover、power supply terminal and meter cover should not less than 100MΩ
      Industrial frequency withstand voltage:
      Between voltage、current input  terminal & power supply terminal and meter cover should withstand 50Hz sine wave 2kV  1min test;Between voltage circuit and current circuit; difference phase of current circuit should withstand 600V test.
      17. Ambient
      Rated temperature:23℃±2℃
      Work temperature range:10℃~30℃
      Max. work temperature range:0℃~40℃
      Storage and transportation max. temperature range:-20℃~55℃
      Relative humidity:≤85%
      18. Others
      Auxiliary power supply: 220V±15%,50Hz±10%
      Power consumption: ≤30VA 
      Cabinet: 355 × 185 × 145 mm。
                              i.              Weigh: 7.5kg

      產(chǎn)品留言
      標(biāo)題
      內(nèi)容
      聯(lián)系人
      聯(lián)系電話
      電子郵件
      公司名稱
      聯(lián)系地址
      驗(yàn)證碼
      點(diǎn)擊換一張
      注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
      2.如有必要,請(qǐng)您留下您的詳細(xì)聯(lián)系方式!
      主站蜘蛛池模板: 精品亚洲国产成人av制服| 亚洲精品国产男人的天堂| 一本大道无码av天堂| 亚洲一区二区经典在线播放| 免费观看欧美猛交视频黑人| gogogo免费高清在线| 少妇激情a∨一区二区三区 | 国产性色的免费视频网站| 日本55丰满熟妇厨房伦| 18禁极品一区二区三区| 国产视频一区二区在线观看| 丰满高跟丝袜老熟女久久| 亚洲国产精品一区二区视频| 中文日韩在线一区二区| 伊人色综合一区二区三区影院视频| 久久精品国产亚洲不AV麻豆| 久久亚洲精品情侣| chinese老太交videos| 国产人妻熟女呻吟在线观看| 99久久精品久久久久久婷婷| 麻豆精品在线| 国产AV无码专区亚洲AV漫画| 免费人成网站视频在线观看| 国产精品欧美福利久久| 无码国产午夜福利片在线观看| 亚洲一区二区三区黄色片| 成人3d动漫一区二区三区| 国产jizzjizz视频| 国产乱人激情H在线观看| 西西少妇一区二区三区精品| 欧洲免费一区二区三区视频| 亚洲人妻av有码一区| 亚洲 日本 欧洲 欧美 视频| 深夜福利资源在线观看| 国产成人精品永久免费视频| 精品人妻系列无码天堂| 亚洲国产高清第一第二区| 精品国产自线午夜福利| 亚洲中文字幕第二十三页| 蜜桃网址| 国产在线中文字幕精品|